Monday–Saturday 08:30–18:30 · 24/7 technical support

Industrial chillers and cooling systems in Turkmenistan

Air-cooled and central chillers, condensing units, dry coolers and cold rooms for projects in Turkmenistan. Units are built at our factory in Konya, Turkey, load-tested and shipped export-ready. The recommendations below are based on the country's climate and power-supply conditions.

Reference city
Ashgabat
Summer avg. high
38.4 °C
Record high
47.2 °C
Record low
−24.1 °C
Power supply
380–400 V · 50 Hz

Chiller selection for conditions in Turkmenistan

Climate values are long-term measurements for the reference city; the site's region and altitude may change them.

  • Summer heat and capacity

    Reference city Ashgabat: average high of the hottest month 38.4 °C, record high 47.2 °C. Air-cooled chillers here must be specified for high-ambient (tropical) duty at 48–52 °C: oversized condenser coils, compressors rated for the higher discharge pressure, shading and no hot-air recirculation.

  • Winter conditions and freezing

    Record low −24.1 °C. About 50% ethylene glycol is recommended for outdoor hydraulic circuits; propylene glycol is used in food processes.

  • Power supply

    Industrial supply: 380–400 V, 50 Hz. Our standard build (380–420 V, 3-phase, 50 Hz) is directly compatible with this supply.

  • Shipping and documents

    Shipping: by road (truck), or by sea in containers where preferred. Each unit is load-tested at the factory and shipped in moisture- and impact-protective packing. Export documents (invoice, certificate of origin, packing list, technical file) are prepared by us.

Source: climate table (Ashgabat). Glycol ratios are approximate; the exact ratio is set from the manufacturer's table.

Recommended products

Final selection is made after the heat load calculation.

Frequently asked questions

How is a chiller selected for Turkmenistan?

First the process heat load is calculated: Q (kW) = flow (m³/h) × 1.163 × ΔT. The unit is then selected for the hottest days at the site (record high 47.2 °C in the reference city) and for the 50 Hz supply.

How are delivery and installation handled?

The unit is built and load-tested at our factory in Konya, Turkey, then packed and shipped. A technical team can be sent for installation and commissioning, or your local team is supported remotely with written documentation.

What information is needed for a quotation?

Process type, required water temperature, flow rate or heat load, maximum ambient temperature at the site, supply voltage and frequency, and the delivery location.

Let's choose the right system for your process together

Send us your machine data or a photo of your plant; our engineers will calculate the heat load and prepare your written quotation within 24 hours.