Compressor and Gas Cooling in Oil and Fuel Facilities

Compressor and Gas Cooling in Oil and Fuel Facilities

Cooling in oil and fuel facilities is needed to keep compressors, process gas and oil circuits at safe temperatures. Gas compressors and auxiliary equipment generate heat continuously; if it is not removed, efficiency falls, equipment trips and downtime increases.

Which equipment needs cooling?

  • Gas compressors: jacket, oil and stage coolers
  • Compressed process gas coolers
  • Hydraulic and lubrication circuits

Selecting the cooling system

Heat loads are taken from the equipment manufacturer's data; depending on the required temperatures and local climate a chiller, a dry cooler or a combination is selected. Redundancy and remote monitoring are recommended for continuous operation.

Hazardous areas (ATEX) and layout

In gas facilities, explosive atmosphere zones are defined by the site risk assessment. The location of the cooling unit, its electrical equipment and piping must follow this classification. In most projects the chiller is placed outside the hazardous zone and reaches the compressors and heat exchangers through a cooling water or glycol line. The final layout is set by the site ATEX documentation and the approval of the responsible engineer.

Equipment cooled at oil and fuel facilities

  • Gas and vapour recovery compressors
  • Pump bearings and seal cooling circuits
  • Hydraulic and lubricating oil circuits
  • Sample coolers and laboratory equipment
  • Air conditioning of electrical and control rooms

Tower, chiller or dry cooler?

Circuits that work at higher temperatures can be cooled without water consumption by a closed-type cooling tower (dry cooler). Circuits needing water below ambient temperature use a chiller. In most facilities both work together: the dry cooler in cooler months and the chiller in summer.

Safety and continuity

Fuel facilities are subject to hazardous area rules. The cooling unit is placed outside these areas and connected to the equipment by a water circuit. For equipment that must run without interruption, redundant pumps and chillers, fault alarms and remote monitoring are recommended.

To see all cooling applications in the energy and gas sector in one place, visit our energy and gas sector cooling page.

Frequently asked questions

Can a chiller replace an existing cooling tower?

Closed-loop chiller or dry cooler solutions can be considered to reduce water loss and fouling; the decision depends on heat load and target temperature.

Can a chiller be placed in the hazardous area of a fuel facility?

A standard chiller is not placed in a hazardous area; the unit is located outside the area boundary and connected to the equipment by a water circuit.

Why is a vapour recovery unit cooled?

Vapour recovery needs low temperatures for condensation; if cooling is insufficient, recovery efficiency falls.

Send us your compressor data and target temperatures; our engineers will calculate the cooling requirement with you.

Work with us

Let's choose the right system for your process together

Send us your machine data or a photo of your plant; our engineers will calculate the heat load and prepare your written quotation within 24 hours.