A gas heat exchanger transfers the heat of compressed or process-heated gas to cooling water. In CNG and natural gas compressors, industrial gas filling, air and nitrogen compressors and process plants, gas is brought down to a safe temperature with these exchangers. Exchanger performance depends directly on the temperature and flow of the water reaching it, so the exchanger and the chiller should be considered together.
Where are gas heat exchangers used?
- Compressor intercoolers: In multi-stage compressors gas is cooled after each stage, so the next stage compresses with less energy.
- Aftercoolers: Gas temperature is lowered before storage, filling or the pipeline.
- Moisture removal: When gas is cooled, the water vapour in it condenses and is removed in a separator.
- Process gas cooling: Hot gases after reaction or combustion are cooled without damaging equipment.
Exchanger types
High-pressure gases usually use shell-and-tube exchangers, with gas inside the tubes and water on the shell side. Lower-pressure applications may use finned-tube or specially designed plate exchangers. Material is chosen according to the gas type, pressure and corrosion risk.
What water should feed the exchanger?
Tower water warms up in summer and carries scale and dirt; deposits in narrow exchanger channels quickly reduce heat transfer. An exchanger fed by a closed circuit and a chiller receives the same water temperature even on the hottest day, and its channels stay clean. Where water does not need to be below ambient, a dry cooler can cool without consuming water.
How is capacity calculated?
On the gas side, heat load comes from gas flow, inlet and outlet temperature and the specific heat of the gas. On the water side the same load is covered by Q (kW) = flow (m³/h) × 1.163 × ΔT (°C). For compressors, the intercooler and aftercooler heat values given by the manufacturer are usually used, with a margin for the hottest summer condition and future compressors.
Maintenance
Scale and dirt on the water side should be checked regularly, filters cleaned and gas and water outlet temperatures recorded. A slowly rising outlet temperature is the first sign of exchanger fouling.
Frequently asked questions
What is the difference between a gas heat exchanger and a chiller?
The exchanger transfers the heat of the gas to water; the chiller is the refrigeration machine that cools this water and sends it back to the exchanger. They work together.
What if the existing gas cooler is not enough?
First check exchanger fouling and water flow. If the problem is water temperature, adding a chiller or closed circuit instead of a tower often solves it without replacing the exchanger.
What information should I send?
Gas type, flow, pressure, exchanger inlet and outlet temperatures and current cooling water data are enough for a capacity calculation.
For other applications in the energy and gas sector, see our energy and gas sector cooling page.
Tell us about your project. Send your product, quantities and location via WhatsApp or e-mail; our engineers will calculate the load and recommend the right system in writing.