Natural gas is cooled at facilities where it is compressed and in processes where moisture must be removed from the gas. Compressed natural gas heats up; if this heat is not removed, compressor efficiency falls, equipment life shortens and overly hot gas goes to the pipeline or storage. Cooling needs vary by facility type.
Where is natural gas cooled?
- Compressor stations: Gas is cooled in an intercooler after each stage and in an aftercooler after the last stage.
- CNG stations: Cooling the gas before vehicle filling lets tanks fill more fully. See our CNG station gas cooling article for details.
- Gas drying: When gas is cooled, water vapour condenses and is removed in a separator, reducing the risk of moisture and icing in the line.
- Auxiliary equipment: Compressor oil circuits, motors and control panels.
Pressure reduction stations are different
At pressure reduction stations the gas temperature drops as its pressure falls. There, heating is usually needed to prevent freezing, not cooling. Cooling needs therefore arise mainly where gas is compressed, and the station type must be defined correctly at the design stage.
Which system is used?
Compressor coolers usually work with gas-water heat exchangers. The water feeding them is cooled by a chiller where a constant temperature is needed, or by a water-free dry cooler where a higher temperature is enough. At stations with several compressors, a central, redundant chiller system ensures uninterrupted operation.
Safety
Natural gas facilities are subject to hazardous area rules. The cooling unit is placed outside this area and connected to the exchangers by a closed water circuit; electrical and control equipment is chosen according to the area classification.
Frequently asked questions
Why is a natural gas compressor cooled?
Gas heats up as it is compressed. Intercooling lets the next stage work with less energy, and aftercooling brings the gas down to a safe temperature for storage and the line.
Can moisture in gas be removed by cooling?
Yes. When gas is cooled, water vapour condenses and collects in a separator. Depending on the required dew point, cooling can be combined with additional drying methods.
How is chiller capacity determined?
The cooler heat loads given by the compressor manufacturer, gas flow and required outlet temperature are used, with a margin for the hottest summer condition and future compressors.
For all applications in the energy and gas sector, see our energy and gas sector cooling page.